Circuit Breaker Timers

       

Digital Circuit Breaker Analyzer

 
       
View Full Specs

The CT-3500 S2 is Vanguard’s second generation, stand-alone, digital, microprocessor-controlled, circuit-breaker timer. It measures the elapsed time from the instant a breaker coil is energized to the instant of opening or closing of a circuit-breaker’s dry contacts. In addition to timing a breaker’s contact response time, the CT-3500 S2 can also time relays or other switching functions that use an initiating trigger voltage (24-300 Volts DC or AC). The timer-triggering voltage starts three independent electronic timers.

  • Detect Main & Insertion Resistor Contacts on same input
  • USB computer interface
  • USB Flash drive interface (Flash drive not included)
  • Store 128 test records internally
  • Initiate Breaker Operation
  • Built-in 2.5" wide Thermal Printer
  • Rugged "QWERTY" style membrane keypad
       

Digital Circuit Breaker Analyzer

 
       
View Full Specs

The CT-6500 Series 2 is a stand-alone, microcomputer-driven EHV Circuit-Breaker Analyzer. It is inexpensive and easy to use. The CT-6500 is available in models with either 3 dry contacts (CT-6500-3); 6 dry-contacts (CT-6500-6); or 12 dry-contact inputs (CT-6500-12). The CT-6500 fully analyzes circuit-breaker performance: contact time, stroke, velocity, over-travel, and contact wipe. Contactmotion analysis includes: Open, Close, Open-Close, Close-Open, and Open-Close-Open. The CT-6500 timing window is selectable: 1-second, 10-second, or 20-second periods.

  • Full Breaker Tabulated & Graphic Data Printout
  • Detect Main & Insertion Resistor Contacts on same input
  • Digital Travel Transducer; no setup or calibration needed
  • Diagnostic ability
  • RS-232C and USB computer interfaces
  • Store 100 timing records
  • Initiate Breaker Operation
  • Built-in Thermal Printer
       

Digital Circuit Breaker Analyzer

 
       
View Full Specs

The CT-7000 Series 2 is a third generation, stand-alone, microcomputer-driven EHV Circuit-Breaker Analyzer. It is inexpensive and easy to use. The CT-7000 is available in models with 3 dry contacts (CT7000-3), 6 dry contacts (CT-7000-6), or 12 dry-contact inputs (CT-7000-12). The CT-7000 fully analyzes circuit-breaker performance: contact time, stroke, velocity, over-travel, and contact wipe. Contact-motion analysis includes: Open, Close, Open-Close, Close-Open, and Open-Close-Open. The CT-7000 timing window is selectable: 1-second, 10-second, or 20-second periods.

  • Full Breaker Tabulated & Graphic Data Printout
  • Detect Main & Insertion Resistor Contacts on same input
  • Digital Travel Transducer; no setup or calibration needed
  • Diagnostic ability
  • USB and RS-232C computer interfaces
  • Store 100 timing records and 99 test plans
  • Initiate Breaker Operation
  • Built-in Thermal Printer
       

Digital Circuit Breaker Analyzer

 
       
View Full Specs

The Model CT-7500 Series 2 is a stand-alone, microcomputer-driven EHV Circuit-Breaker Analyzer. It's inexpensive and easy to use. It operates in either of two modes: as a traditional Time-vs-Travel analyzer or as a Quick-Shot (on-line timing).

  • On-Line Timing
  • Capture First Trip Time
  • Full Breaker Tabulated & Graphic Data Printout
  • Built-in Thermal Printer
  • Initiate Breaker Operation
  • Digital Travel Transducer; No Setup or Calibration Required
  • Support resistor type transducer
  • Detect Main Contact and Insertion Resistor Contact on the Same Input Channel
  • Store 100 records and 99 test plans
  • USB and RS-232C computer interfaces
  • Diagnostic Capabilities
       

Digital Circuit Breaker Analyzer

 
       
View Full Specs

The CT-8000 EHV Circuit-Breaker Analyzer is a fifth-generation design configuration. The Model CT-8000 is a standalone, microcomputer-controlled Circuit-Breaker Analyzer that is inexpensive and easy to use. It operates in either of two modes: As a traditional Time-vs-Travel analyzer or as a Quick-Shot (on-line timing). The CT-8000 is available with either 3 dry contacts (CT-8000-3) or 6 dry contacts (CT-8000-6) configurations. Both models are supplied with 3 digital travel transducer input channels.

  • On-Line Timing
  • Capture First Trip Time
  • Static & Dynamic Resistance Tests
  • Full Breaker Tabulated & Graphic Data Printout
  • Output Test Results to Built-in Thermal Printer
  • Digital Travel Transducer; No Setup or Calibration Required
  • Supports Resistance Type Transducers
  • Detect Main Contact and Insertion Resistor Contact on the Same Input Channel
  • Store 100 records and 99 test plans
  • Computer Interface (RS-232C or USB)
       

EHV Circuit Breaker Analyzer

 
       
View Full Specs

The Vanguard DIGITMR S2 is an inexpensive, easy to use digital circuit breaker analyzer. The DIGITMR S2 can be operated stand-alone or can be computer-controlled. It can fully analyze a circuit-breaker’s performance by testing the contact time, stroke, velocity, over-travel, and contact wipe. Contact and motion analysis can be performed for all breaker contact operations (Open, Close, Open – Close, Close – Open, and Open – Close – Open). Timing results are recorded and displayed on the 240 x 128 pixels back-lit LCD screen and can also be printed on the built-in 4.5" wide thermal printer.

  • Stand-alone, microcomputer-driven EHV Circuit Breaker Analyzer
  • Analyzes contact time, stroke, velocity, over-travel, and contact wipe
  • USB PC interface
  • USB Flash drive interface
  • Can store up to 200 test records and 100 test plans
  • Built-in thermal printer
       

PC-controlled EHV Circuit Breaker Analyzer

 
       
View Full Specs

The Vanguard DIGITMR S2 PC is an inexpensive, easy to use digital circuit breaker analyzer that is designed to be used with a PC. This inexpensive analyzer offers the most cost-effective method for testing circuit breakers. It can fully analyze a circuit-breaker’s performance by testing the contact time, stroke, velocity, over-travel, and contact wipe. Contact-motion analysis can be performed for all breaker contact operations (Open, Close, Open – Close, Close – Open, and Open – Close – Open).

  • Inexpensive, PC-controlled EHV circuit breaker analyzer
  • Optional "on-line" timing mode
  • Small and light-weight
  • Can test contact time, stroke, velocity, over-travel, and contact wipe
       

 
       
View Full Specs

The Doble Transducer Adapter can be used to interface any Doble travel transducer to a Vanguard circuit breaker analyzer.

       

Molded Case Circuit Breaker Tester

 
       
View Full Specs

The Vanguard MCCB-250 is a programmable, high-current source designed specifically for testing molded-case circuit breakers, thermal magnetic and solid-state overload motor-protection relays.

  • 4 current-source outputs (i.e., 5 A @ 120 Vac, 25 A @ 24 Vac, 120 A @ 6 Vac, 250 A @ 3 Vac)
  • 4-line by 20-character LCD display
  • Provides external current input (0-10 A)
       

 
       
View Full Specs

The Vanguard Resistor Transducer Adapter (RTA) can be used to connect any resistor type transducer to the digital transducer channel of a Vanguard circuit breaker analyzer. The RTA also features a 3-pin SwitchCraft connector that can directly interface with ABB resistor transducers.

       

Universal Power Supply

 
       
View Full Specs

The Vanguard Universal Power Supply Series 2 (UPS-S2) is designed and produced to meet a utility company's substation needs for an independent AC/DC power source. Both the AC and DC Voltage sources are capable of supplying 10 amperes continuously.

  • Isolated variable 1-300 Vdc source
  • Isolated variable 1-240 Vac source
  • 10 ampere continuous current
       

Field Pictures

   
       
Rotary Transducer on Federal Pacific Breaker
Testing Areva DT1 245-H1 Breaker
Resistor Transducer on Vacuum Circuit Breaker
Linear Transducer on Areva DT1-72.5F
Rotary Transducer on Megna Blast Breaker
Mitsubishi 500-SFMT Transducer Application
ABB 72PM Circuit Breaker with Linear Transducer and Special Timing Rod
Rotary Transducer on Alstom Breaker
String Transducer on ABB PM72 Breaker
Westinghouse SFA Transducer
Timing Siemens CB at ISA Bacata Substation, Colombia
CT-8000 at LKH Switchgear in Malaysia
CT-8000 Training for TNB Malaysia
Testing CB in Turkey
CB Testing at UluSoy Elektrik, Turkey
DigiTMR Training in Turkey
Testing CB in Salamanga, Mexico
Doble Transducer Adapter Connected to Doble TR3189 Motion Transducer
Doble Transducer Adapter Connected to Doble Rotary Transducer
Doble Transducer Adapter Connected to Doble TR3190 Digital Rotary/Linear Transducer