Product Categories

       

Featured Products

   
       
  • On-Line Timing
  • Capture First Trip Time
  • Static & Dynamic Resistance Tests
  • Full Breaker Tabulated & Graphic Data Printout
  • Output Test Results to Built-in Thermal Printer
  • Digital Travel Transducer; No Setup or Calibration Required
  • Supports Resistance Type Transducers
  • Detect Main Contact and Insertion Resistor Contact on the Same Input Channel
  • Store 100 records and 99 test plans
  • Computer Interface (RS-232C or USB)
  • Perform Saturation, Ratio and Polarity Tests
  • Perform CT Winding Resistance Test
  • Fully Automated
  • Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
  • Plot Multiple Saturation Curves
  • Store 140 Records (of 10 Saturation Curves)
  • Computer Interface
  • USB Flash drive interface
  • Performs CT excitation, current-ratio, polarity, and phase angle tests
  • Measures insulation resistance and winding resistance of the CT seconday windings
  • Measures the CT's secondary burden
  • Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
  • Built-in 4.5-inch wide thermal printer
  • Plot Multiple Saturation Curves
  • Stores up to 128 CT test plans
  • RS-232C, USB, USB Flash drive interface
  • Standalone or computer-controlled
  • Inexpensive
  • Displays turns-ratio from 0.8-15,000
  • Calculates turns-ratio percentage error
  • Displays winding polarity and phase angle
  • Displays excitation current
  • Standalone or computer-controlled
  • Inexpensive
  • Displays turns-ratio from 0.8-15,000
  • Calculates turns-ratio percentage error
  • Displays winding polarity and phase angle
  • Displays excitation current
  • Battery or AC-Powered
  • Auto-discharge circuit for operator safety
  • Demagnetizes transformer after test
  • Selectable test current from 1A to 40A
  • RS-232C, USB, and Bluetooth computer interfaces
  • Built-in thermal printer
  • Standalone or computer-controlled
  • Can test CVT's rated up to 765 KV
  • Displays turns-ratios from 75-15,000
  • Calculates turns-ratio percentage error when nameplate voltages are provided
  • Very lightweight: 16.8 lbs. (7.6 Kg)
  • Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
  • Stores test records on-board or on external USB Flash drive
  • 1 to 200A programmable test current
  • Very lightweight: 19.8 lbs. (8.9 Kg)
  • Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
  • Stores test records on-board or on external USB Flash drive
  • 1 to 200A programmable test current
  • Built-in 2.5" wide thermal printer
  • Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
  • Stores test records on-board or on external USB Flash drive
  • 10 to 600A programmable test current
  • Built-in 2.5" wide thermal printer
  • Auto-discharge circuit for operator safety
  • Demagnetizes transformer after test
  • Selectable test current from 1A to 20A
  • RS-232C, USB, and Bluetooth computer interfaces
  • Built-in thermal printer
  • Detect Main & Insertion Resistor Contacts on same input
  • USB computer interface
  • USB Flash drive interface (Flash drive not included)
  • Store 128 test records internally
  • Initiate Breaker Operation
  • Built-in 2.5" wide Thermal Printer
  • Rugged "QWERTY" style membrane keypad
  • A built-in Timer displays contact time in both cycles and milliseconds
  • AC current source with 3 outputs (10A, 40A, 100A)
  • Set of NO/NC dry contacts that change state when a test is initiated
  • AC voltage source for testing relays up to 250 Vac
  • DC Voltage source (0 - 300 Vdc)
  • Volt meter input (0 - 600 V input range)
  • Three power supplies (24 Vdc, 48 Vdc, 124 Vdc)
  • Built-in power resistors
  • Perform three phase test on a transformer without the need to switch cables
  • Can provide individual Delta winding resistance values
  • Can provide individual Wye (with no neutral) winding resistance values
  • Demagnetize transformer after test
  • Selectable test current from 1A to 20A
  • Computer control via RS-232C, USB, or Bluetooth interface
  • Built-in 2.5" wide thermal printer
  • Perform three phase test on a transformer without the need to switch cables
  • Can provide individual Delta winding resistance values
  • Can provide individual Wye (with no neutral) winding resistance values
  • Demagnetize transformer after test
  • Selectable test current from 1A to 40A
  • Computer control via RS-232C, USB, or Bluetooth interface
  • Built-in 2.5" wide thermal printer
  • Stand-alone, microcomputer-driven EHV Circuit Breaker Analyzer
  • Analyzes contact time, stroke, velocity, over-travel, and contact wipe
  • USB PC interface
  • USB Flash drive interface
  • Can store up to 200 test records and 100 test plans
  • Built-in thermal printer
  • Inexpensive, PC-controlled EHV circuit breaker analyzer
  • Optional "on-line" timing mode
  • Small and light-weight
  • Can test contact time, stroke, velocity, over-travel, and contact wipe