- On-Line Timing
- Capture First Trip Time
- Static & Dynamic Resistance Tests
- Full Breaker Tabulated & Graphic Data Printout
- Output Test Results to Built-in Thermal Printer
- Digital Travel Transducer; No Setup or Calibration Required
- Supports Resistance Type Transducers
- Detect Main Contact and Insertion Resistor Contact on the Same Input Channel
- Store 100 records and 99 test plans
- Computer Interface (RS-232C or USB)
- Perform Saturation, Ratio and Polarity Tests
- Perform CT Winding Resistance Test
- Fully Automated
- Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
- Plot Multiple Saturation Curves
- Store 140 Records (of 10 Saturation Curves)
- Computer Interface
- USB Flash drive interface
- Performs CT excitation, current-ratio, polarity, and phase angle tests
- Measures insulation resistance and winding resistance of the CT seconday windings
- Measures the CT's secondary burden
- Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments
- Built-in 4.5-inch wide thermal printer
- Plot Multiple Saturation Curves
- Stores up to 128 CT test plans
- RS-232C, USB, USB Flash drive interface
- Standalone or computer-controlled
- Inexpensive
- Displays turns-ratio from 0.8-15,000
- Calculates turns-ratio percentage error
- Displays winding polarity and phase angle
- Displays excitation current
- Standalone or computer-controlled
- Inexpensive
- Displays turns-ratio from 0.8-15,000
- Calculates turns-ratio percentage error
- Displays winding polarity and phase angle
- Displays excitation current
- Battery or AC-Powered
- Auto-discharge circuit for operator safety
- Demagnetizes transformer after test
- Selectable test current from 1A to 40A
- RS-232C, USB, and Bluetooth computer interfaces
- Built-in thermal printer
- Standalone or computer-controlled
- Can test CVT's rated up to 765 KV
- Displays turns-ratios from 75-15,000
- Calculates turns-ratio percentage error when nameplate voltages are provided
- Very lightweight: 16.8 lbs. (7.6 Kg)
- Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
- Stores test records on-board or on external USB Flash drive
- 1 to 200A programmable test current
- Very lightweight: 19.8 lbs. (8.9 Kg)
- Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
- Stores test records on-board or on external USB Flash drive
- 1 to 200A programmable test current
- Built-in 2.5" wide thermal printer
- Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
- Stores test records on-board or on external USB Flash drive
- 10 to 600A programmable test current
- Built-in 2.5" wide thermal printer
- Auto-discharge circuit for operator safety
- Demagnetizes transformer after test
- Selectable test current from 1A to 20A
- RS-232C, USB, and Bluetooth computer interfaces
- Built-in thermal printer
- Detect Main & Insertion Resistor Contacts on same input
- USB computer interface
- USB Flash drive interface (Flash drive not included)
- Store 128 test records internally
- Initiate Breaker Operation
- Built-in 2.5" wide Thermal Printer
- Rugged "QWERTY" style membrane keypad
- A built-in Timer displays contact time in both cycles and milliseconds
- AC current source with 3 outputs (10A, 40A, 100A)
- Set of NO/NC dry contacts that change state when a test is initiated
- AC voltage source for testing relays up to 250 Vac
- DC Voltage source (0 - 300 Vdc)
- Volt meter input (0 - 600 V input range)
- Three power supplies (24 Vdc, 48 Vdc, 124 Vdc)
- Built-in power resistors
- Perform three phase test on a transformer without the need to switch cables
- Can provide individual Delta winding resistance values
- Can provide individual Wye (with no neutral) winding resistance values
- Demagnetize transformer after test
- Selectable test current from 1A to 20A
- Computer control via RS-232C, USB, or Bluetooth interface
- Built-in 2.5" wide thermal printer
- Perform three phase test on a transformer without the need to switch cables
- Can provide individual Delta winding resistance values
- Can provide individual Wye (with no neutral) winding resistance values
- Demagnetize transformer after test
- Selectable test current from 1A to 40A
- Computer control via RS-232C, USB, or Bluetooth interface
- Built-in 2.5" wide thermal printer
- Stand-alone, microcomputer-driven EHV Circuit Breaker Analyzer
- Analyzes contact time, stroke, velocity, over-travel, and contact wipe
- USB PC interface
- USB Flash drive interface
- Can store up to 200 test records and 100 test plans
- Built-in thermal printer
- Inexpensive, PC-controlled EHV circuit breaker analyzer
- Optional "on-line" timing mode
- Small and light-weight
- Can test contact time, stroke, velocity, over-travel, and contact wipe
|